| Technical Parameters | ||
| Product Model | LC6001 | |
| Product Name | 485/232 hybrid bus module Modbus/RTU Master | |
| System | Power supply voltage | 5V DC(±10 %) |
| Power supply | Current consumption | 200mA |
| Number of channels | 1 | |
| Physical form | RS485/232 bus | |
| Maximum number of nodes | 32 | |
| Communication Data Format | Can be set | |
| Communication rate | Max 115200kbps | |
| synchronous message | Support | |
| NMT message | Support | |
| POD communication mode | Synchronous, Asynchronous, Remote Request | |
| Communication protocol | ModbusRTU main station | |
| Communication timeout detection | Support | |
| Channel-to-channel isolation voltage | 500V | |
| Regular parameters | ||
| Dimensions and Specifications | 100mm × 68mm × 12mm | |
| Operating temperature | -10~55℃ | |
| Storage temperature | -20~+80℃ | |
| Relative humidity | 95% non-condensing | |
| Protection rating | IP20 | |