| 类型 | 类型 | 精密测量型(宽光点) | |||
| 型号 | 模拟量输出 | SDM-030-A | SDM-050-A | SDM-085-A | SDM-120-A |
| RS485输出 | SDM-030-485 | SDM-050-485 | SDM-085-485 | SDM-120-485 | |
| 基准距离 | 30mm | 50mm | 85mm | 120mm | |
| 测量范围 | +4mm | +10mm | +20mm | +60mm | |
| 线性精度 | +0.05%F.S. | +0.05%F.S. | +0.05%F.S. | +0.2%F.S. | |
| (F.S.=8mm) | (F.S.=20mm) | (F.S.=40mm) | (F.S.= 120mm) | ||
| 重复精度 | 0.25μm | 0.5μm | 1 μm | 2μm | |
| 采样周期 | 250us/330us/500us/1ms/2ms/4ms/8ms/16ms | ||||
| 类型 | 类型 | 精密测量型(聚焦光点) | |||
| 型号 | 模拟量输出 | SDM-030S-A | SDM-050S-A | SDM-085S-A | SDM-120S-A |
| RS485输出 | SDM-030S-485 | SDM-050S-485 | SDM-085S-485 | SDM-120S-485 | |
| 基准距离 | 30mm | 50mm | 85mm | 120mm | |
| 测量范围 | +4mm | +10mm | +20mm | +60mm | |
| 线性精度 | +0.05%F.S. | +0.05%F.S. | +0.05%F.S. | +0.2%F.S. | |
| (F.S.=8mm) | (F.S.=20mm) | (F.S.=40mm) | (F.S.= 120mm) | ||
| 重复精度 | 0.25μm | 0.5μm | 1 μm | 2μm | |
| 采样周期 | 250us/330us/500us/1ms/2ms/4ms/8ms/16ms | ||||
| 类型 | 类型 | 精密测量型(聚焦光点) | ||
| 型号 | 模拟量输出 | SDM-250-A | SDM-350-A | SDM-600-A |
| RS485输出 | SDM-250-485 | SDM-350-485 | SDM-600-485 | |
| 基准距离 | 250mm | 255mm | 600mm | |
| 测量范围 | +150mm | +250mm | +400mm | |
| 线性精度 | +0 .2% F.S. | +0 .3% F.S. | +0 .2%F.S. (200至600mm) | |
| (F.S.=300mm) | (F.S.=500mm) | +0 .3%F.S. (600至1000mm)(F.S.=800mm) | ||
| 重复精度 | 5 μm | 5 μm | 10μm | |
| 光源 | 波长 | 红色半导体激光 655nm |
| 最大输出功率 | 1 mW | |
| 激光等级(GB/IEC) | 2类(Class2 ) | |
| 温度特性(参考值) | +0 .05% F.S./℃ | |
| RS-485通信规格 | 半双工 | |
| 外部输入功能 | 测量值保持/峰值保持/峰峰值保持/谷值保持/平均值保持/触发上传/激光开关 | |
| 开关量输出 | 集电极开路NPN或PNP输出,Max100mA/DC30V,残留电压1 .8V | |
| 模拟量输出 | 模拟电流 | 4-20mA,容许负载电阻300Q以下 |
| 模拟电压 | 0-5V,输出阻抗 100Ω | |
| 电源电压 | DC12-24V+10%(脉动P-P10%以下) | |
| 消耗电流 | 100mA以下 | |
| 保护电路 | 逆反接保护、过流保护、短路保护 | |
| 环境参数 | 保护等级 | IP64 |
| 使用环境温度/湿度 | -10~50℃/35~85%RH(无结和结冰) | |
| 存储环境温度/湿度 | -20~ 60℃/35~85%RH(无结露和结冰) | |
| 环境照度 | 白炽灯:3000IX以下 | |
| 耐振动性 | 10~55Hz 双振幅1 .5mm X、Y、Z方向各2小时 | |
| 耐冲击性 | 500m/s2(约50G)X、Y、Z方向各3次 | |
| 线材 | 外壳:压铸铝 | |
| 线缆 | 2米,6芯线 | |
| 重量 | 约85g(含电缆线) | |