电感式M3,M4圆形接近

Inductive M3,M4 circular approach

  • Surge protection, current short circuit protection, reverse polarity protection
  • Action refers to the light more clear
  • It is made of nickel-plated copper with strong anti-interference ability.
  • Outstanding shock, vibration resistance
  • In-tube solid, full epoxy resin tank filling, water-proof, oil-proof, high temperature resistance

Related Recommendations

  • Functional Parameters
  • Resource Download

image

微信截图_202608191736151



ModelTypesFlush M3M4 flushM4 flushM4 flush
NPN outputHT-φ0301-E1 (normally open)HT-φ0401-E1 (normally open)HT-φ041.5-E1 (normally open)HT-0401-E1 (normally open)
HT-φ0301-E2 (normally closed)HT-φ0401-E2 (normally closed)HT-φ041.5-E2 (normally closed)HT-0401-E2 (normally closed)
PNP outputHT-φ0301-P1 (normally open)HT-φ0401-P1 (normally open)HT-φ041.5-P1 (normally open)HT-0401-P1 (normally open)
HT-φ0301-P2 (normally closed)HT-φ0401-P2 (normally closed)HT-φ041.5-P2 (normally closed)HT-0401-P2 (normally closed)
Appearance电感式M3电感式M3.png电感式M4电感式M4.png
Detection surfaceFront detectionFront detectionFront detectionFront detection
Detection distance1mm±10%1mm±10%1.5mm±10%1mm±10%
Detecting objectsmagnetic metal
Standard detection object (iron)3x3x1mm4x4x1mm4x4x1mm4x4x1mm
Set distance0-0.8mm0-0.8mm0-1.2mm0-0.8mm
Differential distanceLess than 10% of the detection distance
Response frequency1200HZ1200HZ1200HZ1200HZ
Wire diameter2.8mm2.8mm2.8mm2.8mm
Power supply voltageDC12-24V ripple (p-p) below 10% (DC10-30V)
Leakage currentBelow 0.03mA
action formNO: normally open, NC: normally closed
Control outputLoad current below 100mA (residual constant voltage below 2V)
Show lampAction indicator light (red)
Protection circuitSurge protection circuit, short circuit protection, reverse polarity protection
Ambient temperatureAction:-25- 70 ℃ (no ice, no condensation)
Environmental humidityDuring operation and storage: 35-95% RH (no condensation)
The influence of temperatureThe temperature range is -25-70 ℃, and the detection distance shall change within ± 10% when the temperature changes by 20 ℃.
Effect of voltageWhen the rated power supply voltage fluctuates within ± 15%, the detection distance changes within ± 1%
Insulation impedanceAbove 50MΩ (DC500 megohmmeter) between charging part and shell
Withstand voltageAC1000V 50/60Hz 1min charging unit and shell
Vibration resistance10~55Hz up and down amplitude 1.5mmX, Y, Z direction 2h
Impact-resistant500m/SX, Y, Z each direction 10 times
Connection methodWire lead-out type (standard wire length 2m), special (PUR can be customized) drag chain cable
Shell materialBrass with nickel plating
Protection ratingIp67