电感式交直流接近

Inductive AC/DC approach

  • Surge protection, current short circuit protection, reverse polarity protection
  • Action refers to the light more clear
  • It is made of nickel-plated copper with strong anti-interference ability.
  • Outstanding shock, vibration resistance
  • In-tube solid, full epoxy resin tank filling, water-proof, oil-proof, high temperature resistance

Related Recommendations

  • Functional Parameters
  • Resource Download

image

微信截图_202608191736151



ModelTypesM12 Non-flushM18 flushM18 Non-flushM30 flushM30 Non-flush
Two-wire DCHX-1208-D1 (normally open)HT-1805-D1 (normally open)HX-1808-D1 (normally open)HT-3010-D1 (normally open)HX-3015-D1 (normally open)
HX-1208-D2 (normally closed)HT-1805-D2 (normally closed)HX-1808-D2 (normally closed)HT-3010-D2 (normally closed)HX-3015-D2 (normally closed)
Two-wire ACHX-1208-A1 (normally open)HT-1805-A1 (normally open)HX-1808-A1 (normally open)HT-3010-A1 (normally open)HX-3015-A1 (normally open)
HX-1208-A2 (normally closed)HT-1805-A2 (normally closed)HX-1808-A2 (normally closed)HT-3010-A2 (normally closed)HX-3015-A2 (normally closed)
AC and DCHX-1208-AD1 (normally open)HT-1805-AD1 (normally open)HX-1808-AD1 (normally open)HT-3010-AD1 (normally open)HX-3015-AD1 (normally open)
HX-1208-AD2 (normally closed)HT-1805-AD2 (normally closed)HX-1808-AD2 (normally closed)HT-3010-AD2 (normally closed)HX-3015-AD2 (normally closed)
Appearance交流M12非齐平交流M18齐平交流M18非齐平交流M30齐平交流M30非齐平
Detection surfaceFront detectionFront detectionFront detectionFront detectionFront detection
Detection distance8mm±10%5mm±10%8mm±10%10mm±10%15mm±10%
Detecting objectsmagnetic metal
Standard detection object (iron)12x12x1mm18x18x1mm18x18x1mm30x30x1mm30x30x1mm
Set distance0-6.4mm0-4.0mm0-6.4mm0-8.0mm0-12.0mm
Differential distanceLess than 10% of the detection distance
Response frequency400HZ400HZ400HZ300HZ300HZ
Wire diameter3.8mm4.8mm4.8mm4.8mm4.8mm
Power supply voltageDC12-24V ripple (p-p) below 10% (DC10-30V)
Leakage currentBelow 0.03mA
action formNO: normally open, NC: normally closed
Control outputLoad current below 200mA (residual constant voltage below 1V)
Show lampAction indicator light (red)
Protection circuitSurge protection circuit, short circuit protection, reverse polarity protection
Ambient temperatureAction:-25- 70 ℃ (no ice, no condensation)
Environmental humidityDuring operation and storage: 35-95% RH (no condensation)
The influence of temperatureThe temperature range is -25-70 ℃, and the detection distance shall change within ± 10% when the temperature changes by 20 ℃.
Effect of voltageWhen the rated power supply voltage fluctuates within ± 15%, the detection distance changes within ± 1%
Insulation impedanceAbove 50MΩ (DC500 megohmmeter) between charging part and shell
Withstand voltageAC1000V 50/60Hz 1min charging unit and shell
Vibration resistance10~55Hz up and down amplitude 1.5 mmX, Y, Z direction 2h
Impact-resistant500m/SX, Y, Z each direction 10 times
Connection methodWire lead-out type (standard wire length 2m), special (PUR can be customized) drag chain cable
Shell materialBrass with nickel plating
Protection ratingIp67



ModelTypesM8 flushM8 Non-flushM12 flushM12 Non-flush
Two-wire DCHT-0801-D1 (normally open)HX-0804-D1 (normally open)HT-1202-D1 (normally open)HX-1204-D1 (normally open)
HT-0801-D2 (normally closed)HX-0804-D2 (normally closed)HT-1202-D2 (normally closed)HX-1204-D2 (normally closed)
Two-wire AC

HT-1202-A1 (normally open)HX-1204-A1 (normally open)


HT-1202-A2 (normally closed)HX-1204-A2 (normally closed)
AC and DC

HT-1202-AD1 (normally open)HX-1204-AD1 (normally open)


HT-1202-AD2 (normally closed)HX-1204-AD2 (normally closed)
Appearance交流M8齐平交流M8非齐平交流M12齐平交流M12非齐平2
Detection surfaceFront detectionFront detectionFront detectionFront detection
Detection distance1mm±10%4mm±10%2mm±10%4mm±10%
Detecting objectsmagnetic metal
Standard detection object (iron)8x8x1mm8x8x1mm12x12x1mm12x12x1mm
Set distance0-0.8mm0-3.2mm0-1.8mm0-3.2mm
Differential distanceLess than 10% of the detection distance
Response frequency800HZ
Wire diameter3.8mm
Power supply voltageDC12-24V ripple (p-p) below 10% (DC10-30V)
Leakage currentBelow 0.03mA
action formNO: normally open, NC: normally closed
Control outputLoad current below 200mA (residual constant voltage below 1V)
Show lampAction indicator light (red)
Protection circuitSurge protection circuit, short circuit protection, reverse polarity protection
Ambient temperatureAction:-25- 70 ℃ (no ice, no condensation)
Environmental humidityDuring operation and storage: 35-95% RH (no condensation)
The influence of temperatureThe temperature range is -25-70 ℃, and the detection distance shall change within ± 10% when the temperature changes by 20 ℃.
Effect of voltageWhen the rated power supply voltage fluctuates within ± 15%, the detection distance changes within ± 1%
Insulation impedanceAbove 50MΩ (DC500 megohmmeter) between charging part and shell
Withstand voltageAC1000V 50/60Hz 1min charging unit and shell
Vibration resistance10~55Hz up and down amplitude 1.5mmX, Y, Z direction 2h
Impact-resistant500m/SX, Y, Z each direction 10 times
Connection methodWire lead-out type (standard wire length 2m), special (PUR can be customized) drag chain cable
Shell materialBrass with nickel plating
Protection ratingIp67