| Model | Types | Growth distance M8 flush | Growth distance M8 non-flush | Growth distance M12 flush | Growth distance M12 non-flush |
| NPN output | HT-0802-E1 (normally open) | HX-0804-E1 (normally open) | HT-1204-E1 (normally open) | HX-1208-E1 (normally open) | |
| HT-0802-E2 (normally closed) | HX-0804-E2 (normally closed) | HT-1204-E2 (normally closed) | HX-1208-E2 (normally closed) | ||
| PNP output | HT-0802-P1 (normally open) | HX-0804-P1 (normally open) | HT-1204-P1 (normally open) | HX-1208-P1 (normally open) | |
| HT-0802-P2 (normally closed) | HX-0804-P2 (normally closed) | HT-1204-P2 (normally closed) | HX-1208-P2 (normally closed) | ||
| Appearance | |||||
| Detection surface | Front detection | Front detection | Front detection | Front detection | |
| Detection distance | 2mm±10% | 4mm±10% | 4mm±10% | 8mm±10% | |
| Detecting objects | magnetic metal | ||||
| Standard detection object (iron) | 8x8x1mm | 8x8x1mm | 12x12x1mm | 12x12x1mm | |
| Set distance | 0-1.6mm | 0-3.2mm | 0-3.2mm | 0-6.4mm | |
| Differential distance | Less than 10% of the detection distance | ||||
| Response frequency | 1000HZ | 600HZ | 700HZ | 400HZ | |
| Wire diameter | 3.8mm | 3.8mm | 3.8mm | 3.8mm | |
| Power supply voltage | DC12-24V ripple (p-p) below 10% (DC10-30V) | ||||
| Leakage current | Below 0.03mA | ||||
| action form | NO: normally open, NC: normally closed | ||||
| Control output | Load current below 200mA (residual constant voltage below 1V) | ||||
| Show lamp | Action indicator light (red) | ||||
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection | ||||
| Ambient temperature | Action:-25- 70 ℃ (no ice, no condensation) | ||||
| Environmental humidity | During operation and storage: 35-95% RH (no condensation) | ||||
| The influence of temperature | The temperature range is -25-70 ℃, and the detection distance shall change within ± 10% when the temperature changes by 20 ℃. | ||||
| Effect of voltage | When the rated power supply voltage fluctuates within ± 15%, the detection distance changes within ± 1% | ||||
| Insulation impedance | Above 50MΩ (DC500 megohmmeter) between charging part and shell | ||||
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and shell | ||||
| Vibration resistance | 10~55Hz up and down amplitude 1.5mmX, Y, Z direction 2h | ||||
| Impact-resistant | 500m/SX, Y, Z each direction 10 times | ||||
| Connection method | Wire lead-out type (standard wire length 2m), special (PUR can be customized) drag chain cable | ||||
| Shell material | Brass with nickel plating | ||||
| Protection rating | Ip67 | ||||
| Model | Types | Growth distance M18 flush | Growth distance M18 non-flush | Growth distance M18 non-flush | Growth distance M30 flush | Growth distance M30 non-flush |
| NPN output | HT-1808-E1 (normally open) | HX-1812-E1 (normally open) | HX-1816-E1 (normally open) | HT-3015-E1 (normally open) | HX-3025-E1 (normally open) | |
| HT-1808-E2 (normally closed) | HX-1812-E2 (normally closed) | HX-1816-E2 (normally closed) | HT-3015-E2 (normally closed) | HX-3025-E2 (normally closed) | ||
| PNP output | HT-1808-P1 (normally open) | HX-1812-P1 (normally open) | HX-1816-P1 (normally open) | HT-3015-P1 (normally open) | HX-3025-P1 (normally open) | |
| HT-1808-P2 (normally closed) | HX-1812-P2 (normally closed) | HX-1816-P2 (normally closed) | HT-3015-P2 (normally closed) | HX-3025-P2 (normally closed) | ||
| Appearance | ||||||
| Detection surface | Front detection | Front detection | Front detection | Front detection | Front detection | |
| Detection distance | 8mm±10% | 12mm±10% | 16mm±10% | 15mm±10% | 25mm±10% | |
| Detecting objects | magnetic metal | |||||
| Standard detection object (iron) | 18x18x1mm | 18x18x1mm | 12x12x1mm | 30x30x1mm | 30x30x1mm | |
| Set distance | 0-6.4mm | 0-9.6mm | 0-12.6mm | 0-12mm | 0-20mm | |
| Differential distance | Less than 10% of the detection distance | |||||
| Response frequency | 400HZ | 300HZ | 250HZ | 200HZ | 100HZ | |
| Wire diameter | 4.8mm | 4.8mm | 4.8mm | 4.8mm | 4.8mm | |
| Power supply voltage | DC12-24V ripple (p-p) below 10% (DC10-30V) | |||||
| Leakage current | Below 0.03mA | |||||
| action form | NO: normally open, NC: normally closed | |||||
| Control output | Load current below 200mA (residual constant voltage below 1V) | |||||
| Show lamp | Action indicator light (red) | |||||
| Protection circuit | Surge protection circuit, short circuit protection, reverse polarity protection | |||||
| Ambient temperature | Action:-25- 70 ℃ (no ice, no condensation) | |||||
| Environmental humidity | During operation and storage: 35-95% RH (no condensation) | |||||
| The influence of temperature | The temperature range is -25-70 ℃, and the detection distance shall change within ± 10% when the temperature changes by 20 ℃. | |||||
| Effect of voltage | When the rated power supply voltage fluctuates within ± 15%, the detection distance changes within ± 1% | |||||
| Insulation impedance | Above 50MΩ (DC500 megohmmeter) between charging part and shell | |||||
| Withstand voltage | AC1000V 50/60Hz 1min charging unit and shell | |||||
| Vibration resistance | 10~55Hz up and down amplitude 1.5mmX, Y, Z direction 2h | |||||
| Impact-resistant | 500m/SX, Y, Z each direction 10 times | |||||
| Connection method | Wire lead-out type (standard wire length 2m), special (PUR can be customized) drag chain cable | |||||
| Shell material | Brass with nickel plating | |||||
| Protection rating | Ip67 | |||||